Filling Blower Oil
Label | Component |
|---|---|
A | Breather / Oil fill |
B | Sight glass / Oil overflow plug |
C | Oil drain plug |
Oil Required
Approximately 370 ml of ROOTS Synthetic ISO 220 oil.
Procedure
Remove the breather vent (A) and the sight glass (B).
Add oil through the oil fill (A) until oil begins to flow out of the opening (B).
Reinstall the sight glass (B). The oil level should be at the middle of the glass.
Reinstall the breather vent (A).
Wait 5 minutes for the oil to drain down, then check that the oil level is still at the middle of the sight glass (B).